Olimpia splendid AQUARIA 14 P Instrucciones Para La Instalación, Uso Y Mantenimiento página 49

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
After a certain period of operation, when the percentage of humidity in the room is lower than the set
value, the compressor stops temporarily.
Periodically, when the appliance is working (ON mode), dehumidification can be temporarily interrupted
in order to defrost the heat exchanger.
Upon switching on, the appliance starts in "Dehumidification" mode.
3.3 - MODE SELECTION
3.3.a - Laundry mode
Press the "Laundry" key (D5), the appliance starts in "CO" (continuous cycle) mode.
The compressor and the fan continue to work independently from the detected level of humidity.
In this mode the fan will work at maximum speed.
3.3.b - Dehumidification mode
Press the "Dehumidification" key (D5), the appliance starts with the percentage of humidity set during
the last use, press the "Setting level of humidity" key (D4) to change it.
3.4 - WATER UNLOADING
3.4.a - Emptying the tank
• When the led "Water tank full" (L4) switches on, the appliance stops, the buzzer rings and it is nec-
essary to empty the tank (7).
• Remove the tank (7) from the appliance body working with both hands (Fig.7).
• Empty the tank (7) (Fig.8).
Do not remove the float (7b) from the water tank (7). The full water sensor won't
be able to correctly detect water level anymore.
• Correctly reposition the tank (7) in the appliance body, otherwise the led (L4) remains turned on and
the appliance doesn't work.
3.4.b - Continuous water unloading
• If desired, it is possible to connect the supplied hose (14) to the connection (13) to continuously drain
water collected by dehumidification.
• Switch off the appliance and disconnect the plug from the power socket.
• Connect the rubber hose (14) with an internal diameter of 10mm to the connection (13) (Fig. 9).
• It is advised to fix the hose (14) to the connection (13) using a clamp (not supplied).
• Correctly reposition the tank (7) in the appliance body making the hose (14) pass in specific seat
located in the tank (7). If this operation is not completed, the led (L4) remains on and the appliance
doesn't work.
Make sure the rubber hose (14) doesn't exceed the exhaust joint height,
otherwise water will remain in the appliance and could cause a malfunction,
damage it and/or cause dangerous work conditions.
EN - 19
AQUARIA S1 10/12/14/16 P
loading