Berner BHFB 05/12V EVO Instrucciones De Uso página 13

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
d. Yellow light flashing, Green and red LED light on:
Charging the highlydischarged battery takes longer.
After a charging time of 36 hours yellow LED lights up
(defective battery)
e. Yellow light on:
Defective battery
f. Green light on, red light flashing:
The battery is already charged at least 75%.
g. Green light on only:
Battery is fully charged and is under maintaining will auto-
matically adjust the voltage/current relationship to maintain
the battery at a full charge. The battery is ready for a load
test or return to serve. If the battery voltage drops below 12.8
volts, the charger shifts automatically into charging mode
and recharges to an OCV of 14.8 volt. If you are interrupting
the charging process of a battery installed in a vehicle, first
disconnect the battery cable from the chassis and then the
other battery cable.
Attention! The housing of the appliance is hot during op-
eration, since the housing parts have a cooling function.
This is not a fault of the device !!!
Attention: The BHFB 05/12V EVO is not suitable for
voltage maintenance during diagnosis / SERVICE !!!
For this purpose, you need a battery charger from the
-Berner-BHFL series !!!
(EN)
d.
!
e.
f.
75%
g.
OK
loading

Este manual también es adecuado para:

416140