Wilo -Sub TWI4 Serie Instrucciones De Instalación Y Funcionamiento página 18

Ocultar thumbs Ver también para Wilo-Sub TWI4 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
English
10 Faults, causes and remedies
Only have faults remedied by qualified personnel!
Follow the safety instructions in Maintenance.
Faults
Pump does not start.
Pump running but does
not pump.
The volume flow is too low.
The pump starts too often.
If the operating fault cannot be remedied,
please consult a skilled professionals or the
nearest Wilo after-sales service or representa-
tive office.
11 Spare parts
Spare parts may be ordered via local professional
technicians and/or the Wilo after-sales service.
To avoid queries and incorrect orders, all data on
the name plate should be submitted for each
order.
Subject to change without prior notice!
16
Causes
Incorrect voltage or voltage drop.
Breaks in the connecting cable.
The motor protection switch has been
triggered.
The pump starts too often.
No water or the water level is too low
The suction filter is blocked
Incorrect direction of rotation (DM version)
The difference between the switch-on and
switch-off pressure too low
Electrodes are installed incorrectly.
The diaphragm expansion tank is too small
or has incorrect supply pressure.
Remedy
Check voltage during start, a too narrow a
cable cross-section can lead to a voltage
drop and the pump does not start.
Measure the phase resistances, pull up the
pump and check the cable.
Check the protective switch setting of the
triggering current strength and compare it
with the nominal current being drawn.
Reduce the number of starting procedures,
danger of motor overheating
(approx. 1 min.).
• Check the water level, ensure there is
min. 0.20 m water above the suction port.
• Vent pump.
Pull up the pump and clean the filter.
Change two phases in the connection box.
Increase the difference between the
switch-on and switch-off pressure.
Arrange the electrodes at a distance from
each other so adequate time between pump
standstill and pump operation is guaran-
teed.
Check and regulate the pressure (switch on
and off). Check the tank supply pressure.
Replace the diaphragm expansion tank with
a larger one or supplement with an addi-
tional diaphragm expansion tank.
WILO SE 10/2021
loading

Este manual también es adecuado para:

Wilo-sub twi6 serie