Other, pump-specific faults not detectable by
the frequency converter.
Faults
8.1 The pump is run-
ning but does not
pump anything
8.2 The pump is
vibrating
8.3 The pump does
not provide suf-
ficient pressure
8.4 The delivery rate
is irregular

9 Spare parts

Spare parts must be ordered from the local autho-
rised dealer and/or from Wilo after-sales service.
In order to avoid unnecessary inquiries or incor-
rect orders, specify at the time of your order all of
the data listed on the name plate.
10 disposal
Information on the collection of used electrical
and electronic products
Proper disposal and appropriate recycling of this
product prevents damage to the environment
and dangers to your personal health.
NOTICE: Disposal in domestic waste is forbid-
den !
In the European Union, this symbol can appear
on the product, the packaging or the accompa-
nying documentation. It means that the electrical
and electronic products in question must not be
disposed of along with domestic waste.
To ensure proper handling, recycling and disposal
of the used products in question, please note the
following points:
28
Causes
a) The pump is not running fast
enough:
b) Interior parts are blocked by foreign
matter:
c) Suction line is blocked:
d) Air intake through suction line: 
e) The pump has run empty:
f) The suction pressure is too weak,
cavitation noise is occurring gene-
rally:
a) Poorly mounted to the pedestal:
b) Foreign matter is blocking the
pump:
c) Difficult pump rotation:
a) Insufficient motor speed:
b) The motor is defective:
c) Insufficient pump filling:
d) The drainage screw is not screwed
in all the way:
a) The suction head (Ha) has not been
maintained:
b) The suction line has a smaller circ-
umference than that of the pump:
c) Suction strainer and suction line are
partially blocked:
Elimination
a) Check correct setting of the nominal values (setpoints)
(matching of the nominal value points).
b) Dismantle pump, replace defective parts, perform clea-
ning.
c) Clean the entire pipework.
d) Check the impermeability of the entire pipe up to the
pump and seal.
e) Refill the pump. Check the impermeability of the foot
valve.
f) Excessively large suction pressure losses or excessively
large suction head. (check the Net Positive Suction
Head of the installed pump and of the installation).
a) Check and tighten the nuts on the pedestal bolts.
b) Dismantle and clean the pump.
c) Check whether the pump rotates freely without
encountering abnormal resistance.
a) Check correct setting of the nominal values (setpoints)
(matching of the nominal value points).
b) Have the motor/frequency converter replaced.
c) Open the drain cock of the pump and bleed until there
is a complete absence of bubbles.
d) Check drainage screw and screw in as needed.
a) Consult the installation conditions and recommen-
dations contained in these Installation and operating
instructions.
b) The suction line must have the same diameter as the
suction inlet of the pump.
c) Dismount and clean.
• Only hand over these products at designated, cer-
tified collecting points.
• Observe the locally applicable regulations!
Please consult your local municipality, the nearest
waste disposal site, or the dealer who sold the
product to you for information on proper disposal.
For further information on recycling, go to www.
wilo-recycling.com.
Subject to technical alterations!
WILO SE 09/2021
Tabla de contenido
loading

Tabla de contenido