Setting the SSW-08
4.2 KICK START
4
Soft-Starter SSW-08 offers a Kick Start function for loads that present a large initial resistance
to movement.
This function is enabled through the Kick Start DIP Switch. The duration of the voltage pulse is
set through the trimpot Kick Start Time.
The voltage pulse applied is of 80 % Un during the programmed trimpot Kick Start Time.
NOTE!
Use this function only for specific applications and where necessary.
4.3 INITIAL VOLTAGE SETTING
Set the initial voltage to a value that the motor starts to run as soon as the start command is
given to the SSW-08.
26 | SSW-8
Kick Start Enabling
DIP Switch
Figure 4.2: Kick Start enabling
Initial Voltage
Setting Trimpot
Figure 4.3: Initial voltage setting
The dot
indicates the
factory default
setting