Orbegozo FO 6500 Manual De Instrucciones página 9

Idiomas disponibles

Idiomas disponibles

FO 6500
INSTALLING THE APPLIANCE
This appliance must only be installed outdoors.
Before installing, make sure that the gas type and pressure and the appliance specifications are
compatible.
The appliance specifications must be written on the label (or the data plate).
The support must resist a temperature of at least 80 degrees Celsius.
The appliance must be installed in accordance with current Spanish installation regulations.
All the actions indicated in this manual must be carried out by qualified persons and in accordance
with applicable regulations.
CONNECTING THE GAS
This appliance has a label, located on the back of the gas cooker, indicating the gas pressure.
Before turning on the appliance, check it is compatible with the type of gas and pressure available.
In order to work, the stove must have:
-
1 bottle of gas, only bottled by Official Dealers, in accordance with the gas indicated on the
data plate.
-
1 pressure regulator approved and indicated on the data plate.
-
1 flexible tube approved for gas, with a maximum length of 1.5 m.
-
2 screw clamps for the flexible tube.
Connect the flexible tube to the gas supply inlet on the stove and the regulator, ensuring the
tightness by means of the 2 screw clamps.
Place the bottle on a stable surface and assemble the bottle regulator. Make sure that the flexible
tube does not come into contact with the stove and that it is not subject to any twisting forces. After
opening the regulator, check there is no gas leak by applying soapy water with a brush on the joint of
the flexible tube with the cooker and the regulator. The appearance of bubbles means there is a gas
leak.
The bottle replacement must be done far away from any source of flame.
CHECKING CONNECTION TIGHTNESS
After connecting the gas, the tightness of the joints must be checked. To do so, apply soapy water to
the joints; if bubbles appear it means there is a leak.
NEVER USE A FLAME TO DETECT GAS LEAKS
WARNINGS FOR USE
If the stove has been moved, it will be necessary to check that the burner caps are properly fitted.
The appliance runs on BUTANE or PROPANE gas 28‐30/37 mbar.
9
loading