BLUEHELIX TECH RRT 34 C
Plate heat exchanger
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
3
2
•
Isolate the boiler by operating the DHW inlet and system shut-off valves.
•
Open a faucet to drain the domestic hot water.
•
Rotate the box on the panel
•
Drain the water in the boiler through the drain faucet (see *** 'System draining' on page 158 ***)
•
Undo the screws "2"
•
Move the plate heat exchanger back and slide it to the left.
•
Remove the heat exchanger as shown in the figure
•
When refitting the plate heat exchanger, make sure the arrows (indicating: HEATING) are pointing downwards.
Circulating pump
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
2
1
fig. 38
•
Disconnect the power supply and turn off the gas cock ahead of the valve.
•
Electrically disconnect the circulating pump, releasing the connections by raising the detail "1" of fig. 38.
•
Drain the water in the boiler (see "System draining" on page 158).
•
Unscrew and remove the circulating pump motor assembly (fig. 40)
EN
2
1
fig. 37- Plate-type exchanger replacement/maintenance
fig. 39
cod. 3541N270 - Rev. 02 - 11/2017
3
4
fig. 40
183