SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY
OR MAJOR PROPERTY DAMAGE, READ AND
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL
AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump
or in the manual, look for one of the fol-
lowing signal words and be alert to the
potential for personal injury or property
damage.
Warns of hazards that WILL cause
DANGER
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause
WARNING
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause per-
CAUTION
sonal injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND
MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND
WARNINGS PRIOR TO PERFORMING ANY WORK
ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
This pump is not to be used by persons
WARNING
(including children) with reduced physical,
sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the pump by a person re-
sponsible for their safety. Children should be supervised
to ensure that they do not to play with the pump.
Risk of electric shock – this pump is
WARNING
supplied with a grounding conductor. To
reduce the risk of electric shock, install only on a circuit
protected by a ground fault circuit interrupter (GFCI) with
a rated trip current of not more than 30 mA.
This unit contains lubricant oil: always put
WARNING
in place the necessary measures to ensure
that any spilled lubricant does not disperse in the environ-
ment. It is prohibited to dispose of lubricating fluids in the
environment.
If the supply cord is damaged, it may
WARNING
only be replaced by expert and qualified
people in order to avoid a hazard. Only use original
spare parts to replace faulty components. Unsuitable
spare parts may cause the product to work incorrectly and
cause hazards for people and property.
All qualified work must be performed by
WARNING
a qualified technician. Always follow the
National Electric Code (NEC), or the Canadian Electric
Code, as well as all local, state and provincial codes. Code
questions should be directed to your local electrical in-
spector. Failure to follow electrical codes and OSHA safety
standards may result in electric shock, personal injury or
death, and equipment damage. Failure to follow man-
ufacturer's installation instructions may result in electric
shock, fire hazard, personal injury or death, damaged
equipment, provide unsatisfactory performance, and may
void manufacturer's warranty.
Standard units are not designed for use in
WARNING
any swimming pools, open bodies of water,
any water feature including ponds, fountains or waterfalls or
any application where a person can come into contact with
the water in which the pump is submerged. Standard units
are not designed for us with hazardous liquids, or where
flammable gases exist. These fluids and gases may be pres-
ent in containment areas. Tank or wetwell must be vented per
local codes. Failure to follow this warning may result in electric
shock, explosion, fire hazard, personal injury or death.
Only pumps specifically Listed for Class 1,
WARNING
Division 1 are allowable in hazardous liquids
and where flammable gases may exist. See specific pump
catalog bulletins or pump nameplate for all agency Listings.
Disconnect and lockout electrical power
CAUTION
before installing or servicing any electrical
equipment. Many pumps are equipped with automatic
thermal overload protection which may allow an over-
heated pump to restart unexpectedly.
All three phase (3Ø) control panels for submersible
pumps must provide Class 10, quick-trip, overload
protection.
PRE-INSTALLATION CHECKS
Open all cartons and inspect for shipping damage.
Report any damage to your supplier or shipping carrier
immediately.
Important: Always verify that the pump nameplate
Amps, Voltage, Phase and HP ratings match your control
panel and power supply.
Many of our sewage pumps are oil-filled. If there are any
signs of oil leakage or if the unit has been stored for an
extended period check the oil level in the motor dome
and the seal housing, if so equipped.
Check the motor cover oil level through the pipe plug on
top of the unit. The motor chamber oil should just cover
the motor. Do not overfill, leave room for expansion!
To check the seal housing oil level, where used, lay the
unit on its side with the fill plug at 12 o'clock. Remove the
plug. The oil should be within ½" (13mm) of the top. If
low, refill with an ASTM 150 turbine oil. Replace the plug.
You can source oil locally at motor repair shops. Typical
oil brands are: Shell Turbo 32, Sunoco Sunvis 932, Texaco
Regal R&O 32, Exxon Nuto 32 and Mobil DTE Light.
Check the strain relief nut on power cable strain assem-
blies. Power cables should be torqued to 75 in. lbs. for
#16 cables and 80 in. lbs. for all other cable assemblies.
Seal/heat sensor cables, where used, should be torqued
to 75 in. lbs.
Warranty does not cover damage caused by connecting
pumps and controls to an incorrect power source (volt-
age/phase supply).
Record the model numbers and serial numbers from the
pumps and control panel on the front of this instruction
manual for future reference. Give it to the owner or affix
it to the control panel when finished with the installation.
3