en-us Installation and connection
Before using for the first time
Remove information material, adhesive tape and
1.
protective foil.
Clean the appliance.
2.
~ "Cleaning" on page 23
Water connection
9
CAUTION
Installation and connection of the appliance
must be carried out by authorized technicians
according to the installation instructions
supplied.
To avoid damage to the appliance and to
ensure its proper functioning, it should only be
connected to a drinking water system.
To avoid water damage, a shut-off valve must
be installed.
Water pressure of drinking water system
9
CAUTION
To avoid damage to the appliance, a pressure
relief valve must be installed between the
drinking water connection and the tubing,
should the water pressure exceed the
maximum value.
Note: If the water pressure is too low, this will impair
the relevant functions of the appliance.
Min. 0.2 Mpa (2 bar / 29 psi)
Max. 0.8 Mpa (8 bar / 116 psi)
10
Electrical connection
9
CAUTION
Do not connect the appliance to electronic
energy saver plugs.
Note: You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine-controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
After installing the appliance, wait at least 1 hour
1.
before connecting it to prevent damaging the
compressor.
Check that the outlet was installed according to
2.
the regulations and complies with the
requirements.
Requirements for outlets
Outlet with
Protective conductor60 Hz
Fuse
Maximum simultaneous load
Appliance
6 A
Connect the appliance to an outlet near the
3.
appliance.
The outlet must also be freely accessible
following installation of the appliance.
If free access is impossible, an all-pole isolating
switch must be integrated into the permanent
electrical installation according to the installation
regulations.
9
WARNING
RISK OF ELECTRIC SHOCK!
Never use multiple outlets, extension cords
or adapters.
The appliance must be grounded correctly.
Never cut through or remove the power
cord's third conductor (grounding
conductor).
9
WARNING
RISK OF ELECTRIC SHOCK!
If the power cord is too short, never use
multiple outlets or extension cords. Instead,
please contact customer service.
110 V ... 120 V
10 A ... 16 A
loading