This heater is intended for permanent installation. Be sure
that the heater is not facing the ceiling or inflammable
substances.
Fasten the bracket to the wall by means of 2 dowels at least, passing
through the A holes (fig. 1). Use the B holes just as reference (fig. 1).
The heater can be angled on its bracket in correspondence to the C
screw, and the modules can be pointed in correspondence to the D
couplings (fig. 2 ). When the adjustment has been made, tighten all
the screws.
Ceiling mounting with chains (not provided)
Fasten the chains (having an appropriate length) to the ceiling, and
hook them to the heater in corrispondence of all the four E holes by
means of the "S" shaped rings not provided (fig. 3).
3. TECHNICAL FEATURES
The infrared Industrial Heaters range is constituted by appliances
having one, two, or three modules. Each module can have a 1500
W or a 2000 W lamp. The lamps of the models LG (Low Glare) are
characterized by having a low brightness.
79104
Model
79104ED/
791LGW
791LGWED
Power
220-240 V ~
supply
50-60 Hz
Power
1 x 2000 W
Current
Lamps
Range
9-12 m²
Weight
2,1/2,6 kg
Cable H05RN-
F (
3 x 1.5 mm²
min.section)
4. USE INSTRUCTIONS
The Industrial infrared heater was designed for zone heating on large
premises. Production departments, churches, gymnasiums are ideally
79204
791N
792N04
79204ED/
792LGW
792LGWED
220-240 V ~
50-60 Hz
2 x 2000 W
9 A
18 A
1
2
12-16 m²
2,8/3,4 kg
3 x 2.5 mm²
79304
793N04
79404
79304ED/
79404ED/
793LGW
794LGW
793LGWED
794LGWED
380-415 V ~
220-240 V ~
50-60 Hz
50-60 Hz
3P+N
3 x 2000 W
1 x 1500 W
3 x 9 A
7 A
3
1
16-20 m²
7-9 m²
3,9/4,4 kg
2,1/2,6 kg
5 x 1.5 mm²
3 x 1.5 mm²
12
79504
79604
79504ED/
79604ED/
795LGW
796LGW
795LGWED
796LGWED
380-415 V ~
220-240 V ~
50-60 Hz
50-60 Hz
3P+N
2 x 1500 W
3 x 1500 W
14 A
3 x 7 A
2
3
9-12 m²
12-15 m²
2,8/3,4 kg
3,9/4,4 kg
3 x 2.5 mm²
5 x 1.5 mm²