OPERATION INSTRUCTIONS
PRE-START PROCEDURES:
1. Inspect the compressor for any damaged components. Do not operate if compressor is damaged.
2. Verify that the tanks have been drained and are clear of any moisture or dirt (See"Draining Tank").
START-UP PROCEDURES:
1. Verify that the On/Off switch is in the Off position.
2. Verify that the tank air pressure is at 0 PSI.
3. Attach the air hose to the discharge line.
4. Plug the unit into a properly grounded outlet.
5. Press the power switch once. The compressor will automatically cycle on and off to keep the tank
pressure maintained.
6. Adjust the pressure regulator to the proper pressure setting required for the air tool.
SHUT-OFF PROCEDURES:
1. Press the power switch once to shut off the compressor.
GENERAL MAINTENANCE
SERVICE AND MAINTENANCE:
Prior to performing service and maintenance to the compressor, always disconnect all accessories and
attachments from the unit, and disconnect the compressor from the electrical source. When replacing parts,
only use Genuine BOSTITCH replacement parts.
Notice!: This compressor is equipped with an oil-free pump. There is no oil to replace or check.
DRAINING TANK - TWIST-STYLE DRAIN COCKS:
1. Verify that the compressor is turned Off.
2. Holding the handle, tilt the compressor toward the drain cock so that they are positioned at the bottom of
the tank.
3. Turn the drain cock to open the valve.
4. Keep the compressor tilted until all moisture has been removed.
ANY OTHER SERVICE SHOULD ONLY BE PERFORMED BY AN AUTHORIZED
BOSTITCH SERVICE CENTER