 Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle
oil through the spark plug hole into the combustion
chamber.
 Leaving the spark plug out, pull the starter cord two or
three times to coat the inside of the cylinder wall.
 Inspect the spark plug and clean or replace, as necessary.
 Reinstall the spark plug, but leave the spark plug wire
disconnected.
 Clean the air filter.
 Extend the recoil starter rope to check its condition. If
the rope is frayed, have it replaced immediately by an
authorized service center.
 Remove all hoses. Coil the hoses and store as shown.
Do not allow the hose to become kinked.
MAINTENANCE
 Store the unit and accessories in an area that does not
reach freezing temperatures. Do not store near furnace or
other sources of heat that could dry out the pump seals.
PREPARING FOR USE AFTER STORAGE
 Pull the recoil starter grip three or four times to clean
lubricant from the combustion chamber.
 Remove spark plug from the cylinder. Wipe oil from the
spark plug and return it to the cylinder.
 Reconnect the spark plug wire.
 Refuel the machine as described earlier in the operator's
manual.