Herschel SUMMIT 2600 Instrucciones De Instalación Y Funcionamiento página 4

Idiomas disponibles

Idiomas disponibles

Figure 1. Rear of SUMMIT 2600R & 2600 showing power box location
RED is to be connected to Live 2;
GREEN is to be connected to GROUND.
Re-fit and screw-down the power box lid.
MOUNTING POSITION:
The SUMMIT must be installed paying special attention to the minimum clearances stated in these
instructions. The heater must be mounted on a rigid fixing. The ideal position of the SUMMIT is on a ceiling
directly above the area to be heated. If this is not possible, SUMMIT can be mounted on a wall and angled
downwards.
The recommended installation height of the SUMMIT is 2.1m to 2.7m / 83"to 106" from the floor according
to the expected application (see Figure 2). Under no circumstances is the unit to be installed at less than
1.8m / 71" from the floor. In all cases it should be installed at a height where it cannot be touched in
operation.
Figure 2. SUMMIT heated area and applications
The Far Infrared heat of SUMMIT is characterised by a consistent, comfortable heat distribution over the
heated area. The zone heated by the SUMMIT will increase in size the higher the heater is installed from the
floor, but the warmth experienced from the heater will be lower. The mounting height and intensity should
reflect the intended use of the heater.
Mount the heater at a lower height in areas intended for low physical activity (for example a seating area)
or areas subject to airflow (outside or near open doors).
Mount higher where less intense warmth is needed (for example warehouses where workers are active and
wear warm clothing).
To fit the power cable:
Unscrew the lid from the power box on the rear of the
heater and gently prize out the circular blanking plate (for
power cable access).
Fit the 22.3mm / 7/8 " cable gland supplied into
the lid to provide water ingress protection to
the mains power cable.
Connect the external mains supply wiring to the internal wiring
using the spring screw terminals supplied. Colour coding used in
the internal power cable is as follows:
• BLACK is to be connected to Live 1 (hot);
ENGLISH