Mx Onda MX-PG2202X Manual De Usuario E Instalacion página 38

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Connection of the gas supply by rigid tube
The gas outlet must have a key to cut the gas supply to the plate, if you need to
use the elbow adapter, remember to insert the gaskets. After the installation,
check that there are no gas leaks.
Connection of the gas supply by flexible tube
Use the elbow adapter together with the adapter for the flexible hose with the
corresponding sealing gaskets. The flexible tube must be approved and its
length can not exceed 2 meters in length. After the installation, check that there
are no gas leaks and that the hose is not crushed or deformed.
Electric connection
Connect the plug to a mains socket of 220/240 V ~ 50 Hz and that is provided
with an earth connection.
Position the power cable in such a way that it does not touch any surface that
may acquire high temperatures (the chassis of an oven, for example).
CHANGE OF THE TYPE OF GAS ON THE PLATE
The gas plate comes from the factory with the injectors for BUTANE GAS
(G30), if you want to change it to GAS NATURAL (G20) you must use the
injectors supplied in the accessory bag.
The injectors are marked with the diameter of the hole of the outlet for the gas,
and it is very important that you pay close attention when placing them since if
you get confused you can have a very large flame in the small burner or a very
small flame in the the big burner.
Install the injectors as indicated in the following table:
Burner size
Semi fast (medium)
Triple ring (large)
Supply pressure
NATURAL GAS (G20)
Injector marking
0.97
1.25
20 mbar
11
BUTANE GAS (G30)
Injector marking
0.67
0.93
30 mbar
loading