Programming
2a to 2b
This jumper configuration changes the fill temperature
for the rinses from cold to warm for all cycles. Refer to
Figure 15.
4b
2b
0b
Figure 15
10a to 10b
This jumper configuration changes the water level for
the wash segment from low to high for all cycles.
Refer to Figure 16.
12b
10b
8b
Figure 16
7. After the jumpers have been set, replace the
control module cover.
8. Close and lock the top cover.
9. Reconnect power to the machine.
12
4
4a
2
2a
0
0a
12
12a
10
10a
8
8a
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming the Digital Coin Meter
Verify the software version to be a single-coin acceptor
or a dual-coin acceptor by checking the label on the
coin counter board located in the control module
behind the coin meter face. Refer to Figure 17.
For single-coin acceptors, the software version
identification code is "ONECOIN V2.62"; for
dual-coin acceptors, the code is "TWOCOIN V2.85".
1
Left Program Button
2
Right Program Button
3
Coin Counter Board
Figure 17
1
2
3
B164R