10. Specifications
Specifications
Permissible temperatures
Operating temperature
■
Storage temperature
■
EN
Dimensions
Case material
Ingress protection
Weight
Electrical connection
Programmable features
Case designs
(see dimensions)
Electromagnetic compatibility
(EMC)
Only for connection to a certified intrinsically safe circuit with the
following maximum values
Maximum values
Maximum terminal voltage U
Maximum current l
Maximum power P
Maximum capacitance C
Maximum inductance L
For further specifications see WIKA data sheet AC 80.11 and the order
documentation.
28
Model DIH10-Ex (display module)
0 ... 60 °C
-20 ... +80 °C
Ø 43.0 / 48.5 / 62.5 mm x 37 mm
Polycarbonate
Front: IP67
Connection: IP20 or IP00
approx. 55 g
Plug-in terminal strip, up to 1.5 mm²
open cable ends
Scale range, display time, decimal point,
unit (°C/°F), zero point stabilisation,
programming lock, programmable points,
TAG number
■
■
EN 61326 emission (group 1, class A) and
immunity (industrial application)
DC 30 V
0
100 mA
0
1 W
0
negligibly small
i
negligibly small
i
WIKA operating instructions model DIH10-Ex
Connection head (standard)
Case with pipe support