3. Specifications / 4. Design and function
Process connection
In accordance with the general technical regulations for pressure
gauges (e.g. EN 837-2 "Selection and installation recommendations for
pressure gauges"), plastic, G 1/8 female threads
Permissible temperature
Ambient:
-30 ... +80 °C
Medium:
-16 ... +50 °C
Temperature effect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529, optional IP 65
EMC directive
Per EN 61000-6-4 and EN 61000-6-2 (cable length max 30 m)
For further specifications see WIKA data sheet PM 07.40, PV 17.40 and
the order documentation.
4. Design and function
Description
Nominal size 110 mm
■
The instruments measure the pressure by means of diaphragms
■
(silicone)
The measuring characteristics are in accordance with the EN 837-3
■
standard and ventilation and air conditioning (VAC) regulations
Scope of delivery
Cross-check the scope of delivery with the delivery note.
WIKA operating instructions air2guide models A2G-10, A2G-15
GB
7