Aritech EV1012PI Manual De Instalación página 3

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
EN: Installation Sheet
Introduction
The EV1012PI is a PIR motion sensor featuring pet friendly
optics.
WARNING!
The equipment is not earthed. Any
external circuit connected to the equipment must be
located within the same building and connected to a
protective earthing conductor.
Wire insulation of cables connected to the equipment must
conform to IEC 60332-1-2 and IEC 60332-1-3 or IEC 60332-
2-2, depending on the wire cross sectional area, or IEC TS
60695-11-21, regardless of cross sectional area. Alternatively,
such wires must comply with UL 2556 VW-1.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals above 35 cm (1 ft.) within the detector field of
view (Figure 7)
Obscuring the detector field of view with large objects,
such as furniture
Installing the detector
Figure 8
(1) Standard connection
(factory default)
(2) Dual loop connection
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, item 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, items 2 and 3).
3.
Fix the base to the wall between 2.3 m and 3.0 m (7.5 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3).
4.
Wire the detector (see Figures 3 and 8).
5.
Select the desired jumper settings (see Figure 6). See
"Jumper settings" below for more information.
6.
Remove the blinders and add the stickers, if required (see
Figure 5 for an example).
For ceiling-mount applications that require a 90° coverage,
7.
use the SB01 swivel-mount bracket.
8.
Close the cover.
9.
Insert the screw and place the custom insert.
Jumper settings
See Figure 6 for the jumper locations in the detector.
J1: Not used
P/N 146253999-6-ML • REV G • ISS 04DEC20
CP Control panel
WT Walk test
J2: PIR enabling the LED
On: Enables the detector LED at all times (default).
Off: Puts the LED under control of the WT (walktest) input. If
the WT input is connected to GND (terminal 1), the red LED
goes on for 3 seconds when a PIR intruder alarm is detected.
If the WT input is connected to +12 V (terminal 2) or floating,
the red LED is disabled.
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect
the detector to any control panel. Use jumpers 3 and 4. See
Figure 8.
LED indication
PIR
Red LED
Start up
Low voltage
PIR intruder
alarm
Continuously on
Normal blinking (1 Hz)
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current consumption
Current consumption in alarm
Maximum current consumption
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Alarm relay To reset
Closed
Automatically after 25 s
Open
Apply correct voltage
(Alarm)
Open
Automatically after 3 s
(Alarm)
PIR
DSP
12 m (39 ft. 4 in.)
9 curtains pet-friendly
No
9 to 15 V
(12 V nominal)
2 V (at 12 V )
25 s
4.4 mA
1.2 mA
11 mA
2.3 to 3.0 m (7.6 to 9.8 ft.)
30 cm/s to 3 m/s (1 ft./s to 10 ft./s)
80 mA, 30 V , resistive
3 s
−10 to +55°C (+14 to 130°F)
108 × 60 × 46 mm (4.25 × 2.36 ×
1.81 in.)
95% max. noncondencing
120 g (4.2 oz.)
IP30 IK02
3 / 22