Parameter menu
Error messages and error clearance
Message/symptom
Display: „- - -
No display function (display
OFF)
No vacuum at desoldering tool
Insufficient vacuum at desolde-
ring tool
Hot air tool has no air
Symbols
Caution!
Read the operating instructions!
Before performing work of any kind
on the unit, always disconnect the
power plug from the socket.
ESD-compatible design and ESD-
compatible workstation
Equipotential bonding
Fuse
Safety transformer
CE mark of conformity
British Conformity Mark
46
Possible cause
Tool has not been detected
Tool defective
No mains supply voltage
Vacuum not connected
Desoldering nozzle clogged
Pump faulty
Filter cartridge on desoldering
tool full
Main filter full
Air hose not connected
Main filter full
Remedial measures
Check connection of tool to
device
Check connected tool
Turn on mains power switch
Check mains supply voltage
Check device fuse
Connect vacuum hose to
vacuum connection
Service desoldering nozzle
using cleaning tool
Change filter cartridge on
desoldering tool full
Change the main filter element
on the soldering station
Connect or check air hose
Change main filter cartridge on
soldering station
Soldering
Desoldering
Hot air
Disposal
Do not dispose of electric tools together
with household waste material! In obser-
vance of European Directive 2012/19/
EU on waste electrical and electronic
equipment and its implementation in
accordance with national law, electric
tools that have reached the end of their
life must be collected separately and re-
turned to an environmentally compatible
recycling facility.
Dispose of replaced equipment parts,
filters or old devices in accordance with
the rules and regulations applicable in
your country.
loading