7.4.3.1 AKM2G-43 Derates for Different Options
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - No Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
0
1000
100.0%
94.6%
99.6%
93.7%
100.0%
94.6%
99.6%
93.7%
100.0%
94.6%
99.6%
93.7%
0
1000
2000
100.0%
94.6%
87.7%
99.6%
93.7%
85.9%
100.0%
94.6%
87.7%
99.6%
93.7%
85.9%
100.0%
94.6%
87.7%
99.6%
93.7%
85.9%
AKM2G Instructions | 7 Technical Data
Speed: RPM
2000
3000
4000
87.7%
80.7%
73.4%
86.3%
78.6%
70.6%
87.7%
79.4%
70.5%
85.9%
76.4%
66.0%
87.7%
79.4%
70.5%
85.9%
76.4%
66.0%
Speed: RPM
3000
4000
79.4%
70.5%
76.4%
66.0%
79.4%
70.5%
76.4%
66.0%
79.4%
70.5%
76.4%
66.0%
Kollmorgen | kdn.kollmorgen.com | August 2018
5000
6000
65.8%
57.7%
62.0%
52.7%
60.6%
49.6%
54.2%
40.1%
60.6%
49.6%
54.2%
40.1%
5000
6000
60.6%
49.6%
54.2%
40.1%
60.6%
49.4%
54.1%
39.7%
60.6%
49.4%
54.1%
39.7%
189