Agatec A110 Guía Rápida página 6

Idiomas disponibles

Idiomas disponibles

To activate this safeguard feature, press and briefly hold the H.I.
key (16) after turning the laser on. The LED (18) will blink rapid-
ly while the laser is self-leveling.
About 30 seconds after the head starts to rotate, the LED (18)
will blink slowly, indicating the H.I. Alert is activated.
If the laser is disturbed while in H.I. Alert mode, the head will
stop rotating, the beam will turn off, the LED indicator (18) will
be on continuously, and an alarm will sound for 30 seconds.
Turn the laser off and turn it on again. Check to see if the beam
elevation has changed from its original benchmark position.
The laser is no longer in H.I. Alert mode. Press and briefly hold
H.I. (16) to return to H.I. Alert.
This feature is only available in automatic mode.
2.4 Rotation
The head rotates at 3 speeds: 0, 150 and 600 rpm. 600 rpm
is the default setting. The laser beam is more visible at slower
rotation speeds.
To increase rotation speed, press the key (13) on the laser.
Press the key (12) to decrease speed. Hold the key (12) to stop
rotation.
When the beam is stopped, the point can be moved to the right
or left using the > or < keys (10 and 11). You can also move
the head manually to position the beam point. To start rotation
again press key (13).
2.5 Scanning
For interior applications, scanning mode allows you to see the
beam easier at a distance.
1. To scan, press (15) on the laser or press the scanning
symbol on the remote control or the detector.
2. The beam will blink until the laser has self-leveled.
8
3. To decrease the scan length, press the key (12); to increase the
scan length, press the key (13). Keys on the remote control or
detector can also be used for the scan functions.
4. To move the scan to the left, use the < key. To move to the
right, use the > key (10 and 11).
5. To stop scanning, again press (15).
2.6 Wall Mount
The wall mount can be used to attach the laser to a ceiling grid
for suspended ceiling installation. It can remain attached to the
laser when placed in the carrying case. Remove the wall mount
when using the laser in vertical mode.
The wall mount's unique design places the laser at the proper height,
so that the beam hits the center of the red magnetic target when the
target is at the correct installation height for the grid.
2.7 Squaring
After placing the laser in vertical position, the plumb beam out
the top of the head can be moved to the left or right. This is
necessary to do squaring for installing walls and partitions.
To position the rotating plane perpendicular to a reference line:
1. Place the laser (without the wall mount) on the ground on the
side with the feet. The beam aperture should be approximately
over your close reference point.
Use this lever to clamp the
wall mount to the ceiling grid
Use for optional security tie
Wall stand-off for short overhangs
When attaching the wall mount, foot
for vertical mode is inserted here
Knob to attach the wall mount
to the laser
9
loading