BADU OmniTronic Serie Traducción De Las Instrucciones Para El Manejo Originales página 116

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 322
Faults/troubleshooting
7
Faults/troubleshooting
7.1
Overview
Two different error messages are displayed on the device itself:
Sensor error – wrong distance from the angle sensor
Time error – position not reached
The number of error messages is displayed in the "Service" menu
item. A distinction is also made there between the number of
sensor and time errors.
Problem: Leak found in pipe to sewer (inspection glass on valve).
Possible causes
Impurities in valve (sand) or on
the seal.
Problem: The backwash/rinse cycle cannot be started via the
right-hand key on the display.
Possible causes
Key not pressed long enough.
Problem: Loud snapping noise in the drive housing.
Solution
Find the cause and repair the fault.
Replace the motor sprocket.
Problem: Valve turns when turned on.
Possible causes
No error.
50 EN
Solution
Backwash in order to
remove any dirt from the
seal.
A function run can be
achieved by switching
on/off at the rocker switch.
Send the actuator and
valve lid to the
manufacturer.
Solution
Press the right-hand key
on the display for more
than 3 seconds.
Solution
Test cycle is started, exact
starting position is
reached.
03|2022
loading

Productos relacionados para BADU OmniTronic Serie

Este manual también es adecuado para:

Omnitronic r41Omnitronic r51