Display
During the tightening process, the current torque is shown in the
display. Information on the current settings is also displayed.
1 Current torque value
2 Current unit of measurement (N · m, in · lb or ft · lb)
3 Data storage set (without the symbol, no data storage)
4 Extension set (without the symbol,
the standard extension is set)
5 Automatic taring set (without the symbol, no automatic taring)
6 Bolting tolerance set (without the symbol, no bolting tolerance)
7 Battery consumption display
8 PIN code entry required
(without the symbol, no PIN code entry required)
9 Cut-out mode set (without the symbol, indicating mode)
1
9
8
Optical display signals
Red
The current torque value lies outside of the set tolerance range.
Green
The current torque value lies within the set tolerance range.
2
3
7
6
5
EN
25