At any setting pages, press STOP to exit or return to the page one.
•
When the unit is working, press STOP to stop running and return to the page one.
•
After entering into different setting pages, press UP and DOWN to change the value.
•
When it is in page one, press TIMER button to enter into timer mode,
•
The detail will be as below:
•
"Interval xxx s": interval time setting
•
"Duration xxx s": duration time setting
•
When in TIMER mode, the fog output will be depended on Timer Out.
•
When press button VOLUME, the timer mode is invalid, and the fog output will be
based on the setting of Volume out.
Set interval
To set the interval, press "Menu" until "Interval set" appears on the display.
Then use the Up/Down buttons to set the fog pause from 5 to 200 seconds.
This setting is required if you want to use the timer mode.
Setting the fog duration
To set the duration, press "Menu" until the display shows "Duration set".
Use the Up/Down buttons to set the fog duration from 1 to 200 seconds.
This setting is required if you want to use the timer mode.
Setting the Fog Level for Timer Mode
To set the fog quantity for the timer mode, press "Menu" until the display shows "Timer out".
Use the Up/Down buttons to set the fog quantity from 1 to 100%.
This setting is required if you want to use the timer mode.
Setting the Fog Level for Volume Mode
To adjust the fog quantity, press "Menu" until the display shows "Volume out".
Use the Up/Down buttons to adjust the fog volume from 1 to 100%.
This setting is required if you want to use the option Volume (Continuous Mode).
Setting the DMX address
To set the DMX address, press "Menu" until the display shows "DMX ADD xxx".
Then use the Up/Down buttons to set the value from 001 to 512.
Activating/deactivating the liquid sensor
Press "Menu" until "Fluid sensor" appears in the display.
Use the Up/Down buttons to activate or deactivate the fluid sensor (On/off).
When the Fluid sensor is activated, the display shows "Ready to Fazer S".
If the Fluid sensor is deactivated, the display shows "Ready to Faze".
Timer Mode
In the timer mode, the fog machine will automatically emit fog. The time intervals, duration
and fog volume depend on the corresponding menu settings. Press the TIMER button, to
activate the timer mode.
The display indicates the set time interval: Interval xxx s
The unit counts down to 0 seconds and emits fog. To deactivate the timer mode, press the
Stop button.
Volume (Continuous Mode)
Press the VOLUME button, to activate continuous fog output. The display indicates Volume
followed by the value that was set in menu item "Volume Out": Duration xxx s
To stop the fog output, press the Stop button.
5