Dometic RC 1205 GC Manual De Instrucciones página 9

Ocultar thumbs Ver también para RC 1205 GC:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
10.2. Connecting to vehicle power
source
Make sure no other energy source is connected (gas,
230V).
A safety fuse must be installed in the electricity supply
between battery and the cooling box in a duct.
12V appliances must be connected to a vehicle
cigarette lighter, which is protected with a 10A fuse.
24V appliances must be connected by inserting a
terminal block and switch and protected with a 5A
fuse. The switch must be suitable for switching a 5A
current.
It is not necessary to consider the polarity when
connecting the unit.
In case you need a longer cable, please refer to the
table below:
Cable cross section
2.5 mm
2
until
4.0 mm
until
2
6.0 mm
until
2
Do not connect a cable thicker than 2.5 mm
cigarette lighter plug! Please build a terminal block
connection.
For your safety:
Do not check for leaks with a naked flame!
max. cable lengths
12 V
24 V
2.5 m
5 m
4.0 m
8 m
6.0 m
12 m
into the
2
10.3. Connection and replacement
of
the gas cartridge
Note the particularly valid national rules for
usage of liqiud gas driven appliances.
Make sure no other energy source is connected
(230V, 12V).
The unit must not be connected to town or natural
gas pipelines. It is suitable for use with self sealing
gas cartridge (CAMPINGAZ CP250, 250g).
Before connecting the gas cartridge, please read
the handling and storage instructions provided on
the side of the cartridge. Check the proper fitting of
the gas cartridge to the connecting port of the
appliance. Before connecting the gas cartridge,
check the cleanliness of the connecting port of the
appliance to the gas cartridge.
Perform this operation in a well-ventilated area, free
from ignition sources. Close the appliance valve. Put
the lever on upper position. Place the cartridge in
the appliance.
While transporting and handling the appliance, the
gas cartridge may not be connected to the
appliance.
Do not smoke while checking for leaks!
GB
9
loading

Este manual también es adecuado para:

Jcb-1