Crosby IP IPGN10 Manual Del Usuario página 4

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
USER MANUAL
For clamp types:
EN
04
© The Crosby Group LLC. Nothing from this original user instructions publication may, in any way
whatever, be replicated or published without prior written permission from The Crosby Group LLC.
1.
General
You have chosen a CrosbyIP lifting clamp.
CrosbyIP lifting clamps are the most reliable lifting clamps available. But using reliable tools does
not automatically mean that practices are reliable. The people who work with clamps play an
equally important role in reliable lifting. Ensure that everyone who works with CrosbyIP lifting
clamps has been instructed in the proper application of the clamps.
CrosbyIP provides a 10 year warranty for its clamps. To keep CrosbyIP lifting clamps in optimum
condition and keep warranty, regular maintenance is important. Preventive maintenance and repair
shall be carried by a repairer authorized by CrosbyIP. In order to benefit from this warranty pro-
gramme and for more details on maintenance procedures, please consult www.thecrosbygroup.
com/resources/crosbyip-10-year-guarantee for more information.
It is not
permitted to stay
Please read and understand these instructions before using the lifting clamp.
in the danger
zone of the load.
2.
Safety precautions
Ensure that the
load remains on
„ Proper instruction for the personnel is of vital importance. This will contribute to maximum
the ground when
reliability in the working environment.
turning.
„ IPGN10 - IPGNS clamps may be applied per piece, per set or several at the same time for the
lifting of plates.
No changes may
„ Ensure that each clamp receives its proportionate share of the load. When using two clamps
be made to
or more, a spreader beam is recommended.
CrosbyIP
„ Hardness: With the clamps IPGNS it is possible to lift steel with a surface hardness of 484
clamps. Never
HV10, with the clamps IPGN10 steel up to a surface hardness of 600 HV10, and with the
straighten,
clamps IPGN10S and IPGNSR stainless steel up to a surface hardness of 363 HV10. For
attempt to bend
harder steel types contact your CrosbyIP Customer Service Centre.
or heat treat
„ Contact your CrosbyIP Customer Service Centre before using this clamp for plates and
parts.
constructions that have a radius.
„ Temperature: the operating temperature is between –40 ºC (–40 ºF) and 100 ºC (212 ºF). For
Clamps suited
other temperatures contact your CrosbyIP Customer Service Centre.
for stainless
„ There are restrictions for operation in special atmospheres (e.g. high humidity, explosive, saline,
steel, must be
acid, alkaline).
used only for
„ Loads: For proper application of the clamp consult the load diagrams 1.
handling
„ Ensure that all attachments between lifting eye and crane are properly fitted, secured and
stainless steel,
coupled.
to avoid contact
„ For each lift only one plate may be transported or lifted.
corrosion.
Copyright © 2021 The Crosby Group LLC. All Rights Reserved.
IPGN10 - IPGNS
Vertical minimal marring lifting
loading

Este manual también es adecuado para:

Ipgns