Low Battery Voltage Warning
If the alarm beeps once every 40 seconds, the FAULT indictor (yellow LED) will flash.
This indicates low battery state.
Notes:
• You need to replace the batteries immediately when the alarm enters this state.
• The alarm will not protect against the risk of carbon monoxide poisoning when the battery has
drained.
• Low battery voltage warning sounds (refer to "4. Battery Replacement").
Low Battery Voltage Warning Silence
When the alarm sounds in the low battery warning state, pressing the TEST/SILENCE
button will result in the alarm being silenced for about 9 hours. The FAULT indicator
(yellow LED) will flash repeatedly.
Note: Replace the battery to ensure normal working condition.
End of Life Warning
If the alarm beeps 3 times every 40 seconds and the FAULT indicator (yellow LED)
flashes, this indicates end of life of the CO detector. In this case, replace the CO detector.
End of Life Warning Silence
When the alarm is in the end-of-life warning, pressing the TEST/SILENCE button will
cause the detector to enter silence status for about 9 hours. The FAULT indicator (yellow
LED) will flash repeatedly.
CO detector Warning
When the alarm detects a dangerous level of CO, the alarm will emit a loud alarm pattern
of 4 short beeps followed by 5 seconds of silence. This cycle repeats itself as long as a
dangerous CO condition exists. The red alarm LED will flash in the same pattern.
This signal will repeat until the alarm resets after dissipation of CO.
Sensitivity Setting: Conforms to EN 50291-1:2018 standard.