FORCED MANUAL DEFROST
CHANGE IN RELATIVE HUMIDITY
TEMPERATURE SETPOINT SETTING/VARIATION
Press and release the key enter: the current setpoint blinks on the display for
5 seconds.
After 5 seconds, the displays shows the room temperature again
While the display is blinking, use the up and down keys to increase or
decrease the temperature setpoint
Press the enter button again to confirm the new set point: the acquisition of
the new value is signalled by an acoustic emission of 3 short consecutive
beeps.
The display returns to the indication of the temperature in the cell.
SMART FUNCTIONS – Quick-access functions
Push the defrost button for more than 3 seconds to access the manual
defrost functions.
With the defrost in progress press the button again for a period greater than 3
seconds to end the defrost phase.
Push the down button, hold down for more than 3 seconds to modify the
percentage of relative humidity in the chamber.
The temporary flashing confirmation label [F_C] corresponds to a too low
relative humidity (fans in parallel with the compressor).
The flashing temporary confirmation label [F_ _] corresponds to a too high
relative humidity (fans independent).
The relative humidity that blinks on the temporary label [FtE] is programmed
by the manufacturer.
Push the up and down buttons simultaneously and hold down for more than 3
seconds.
The label [Loc] is visualised.
Push the enter to confirm the choice and activate the function.
After 30 seconds if not confirmed the program exits the function.
To unlock the keyboard it is necessary to press the
simultaneously for more than 3 seconds: in confirmation of the operation on
the display the message [UnL] appears, flashing, accompanied by 3 short
beeps of the buzzer.
Immediately afterwards, the display returns to the indication of the
temperature in the cell.
With the keyboard locked, pressing any button, the instrument emits a long
beep indicating the [Loc] message on the display.
BLOCKIEREN DER TASTATUR
10
buttons