Steinberg Systems SBS-PT-200S Manual De Instrucciones página 57

Ocultar thumbs Ver también para SBS-PT-200S:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 180
Kzr
Level 2:
1. Turn on the unit while holding down the "ZERO" button. After turning on the
unit and still holding the "ZERO" button, press the "UNIT" button three times.
The unit will go to the list of available functions to adjust.
2. To adjust the displayed parameter, press the "UNIT" button. The parameters
are adjusted using the "TARE" button.
3. To return to the main settings menu or skip a parameter and move to the next
one, press the "ZERO" button.
Available settings:
DISPLAYED
MESSAGES:
CAPu
CAP
CALU
CAL
DIVS
ADC
D. SBS-PT-30SN; SBS-PT-150SN:
equal to the value
"0" after activation
Percentage
weight on the scale
that will enable the
zeroing function
Corresponding
function
Maximum load unit
Maximum load
Calibration unit
Calibration value
Breakdown
ADC processing (in
bits)
of
• 3
• 4
• 5
• 10
Function adjustment options
• kg
• lb
When the "UNIT" button is pressed, "0000"
will be displayed.
• Press the "HOLD" button to mark the desired
digit in the displayed number sequence.
• Press "TARE" to increment the marked digit.
• kg
• lb
When the "UNIT" button is pressed, "0000"
will be displayed.
• Press the "HOLD" button to mark the desired
digit in the displayed number sequence.
• Press "TARE" to increment the marked digit.
• 0.5
• 1
• 2
• 18
• 21