Connecting to the rear
1. Apply supplied fibre glass sealing tape measuring
10 x 3 mm to the contact surface of the connection
collar.
2. Remove the protection plate from the back shield
with the assistance of a screwdriver; see following
figure.
3. Remove the cover (1) from the back wall; see fol-
lowing figure.
4. Fit the connection collar to the back wall with the
materials supplied (5).
5. Apply supplied fibre glass sealing tape (2) meas-
uring 10 x 3 mm to the contact surface of the
cover.
6. Fit the cover to the top plate using the mounting
bracket (3) and materials supplied (4).
Energies se reserva el derecho de realizar cambios por razones técnicas.
Connect to top
On delivery, the connection at the rear is closed, so
that a back cover does not need to be installed.
Because of the distance to the (combustible)
wall, the protection plate may not be removed in the
back shield.
1. Apply supplied fibre glass sealing tape (2) meas-
uring 10 x 3 mm to the connection collar's contact
surface (1).
2. Fit the connection collar to the top plate with the
materials supplied (3).
10