FONESTAR MAX-120Z Manual De Usuario página 7

Idiomas disponibles

Idiomas disponibles

TECHNICAL SPECIFICATIONS
MAX-120Z
FEATURES
Class D PA amplifier and switch-mode power supply SMPS.
USB/FM player.
Microphone inputs with mix, gain and priority level control.
Chime tone generator.
3 auxiliary inputs.
Emergency and mute input for connection to alarm and evacuation systems.
24 V attenuator priority.
Tone controls.
100 V, 70 V and 4 Ω outputs.
Output zones with volume and Off control.
POWER
120 W RMS
RESPONSE
45-22,000 Hz -10 dB (@5W)
DISTORTION
THD+N: < 0.5% at 1 kHz
S/N RATIO
Mic >75 dB, Line >83 dB, Aux >81 dB
PROTECTIONS
Soft start, overcurrent, overload, temperature and short circuit
INPUTS
CH 1: 1 balanced mic/line with 48 V phantom, Combo (XLR + 6.3 mm) and euroblock. Mic: 600 Ω, 5.6 mV
RMS (-45 dBV). Line: 100k Ω, 250 mV RMS (-12 dBV). Contact closure ring tones
CH 2 and 3: 2 balanced mic/line with 48V phantom, euroblock. Mic: 600 Ω, 5.6 mV RMS (-45 dBV).
Line: 100k Ω, 250 mV RMS (-12 dBV). Contact closure ring tones
3 auxiliary, 2 x RCA, 47.000 Ω 316 mV RMS (-10 dBV)
1 emergency line/100 V euroblock. Line: 326 mV RMS (-10 dBV). 100 V line
Mute (Emergency Priority) by contact closure, euroblock
1 Amp-in, RCA, 1.2 V RMS (+ 1.5 dBV)
OUTPUTS
1 REC, 2 x RCA, 316 mV RMS (-10 dBV). Pre-master
1 Pre-out, RCA, 1.2 V RMS (+1.5 dBV)
3 x 100 V loudspeaker zones with 7-position volume selector and OFF, euroblock
1 attenuator priority, 24 V and contact closure
FUNCTIONS
Input priority:
100 V Emergency input with highest priority, attenuates all other inputs
Mute by contact closure, attenuates all inputs except the 100V Emergency input
Channel 1 with priority over all other inputs, level selectable
Channels 2 and 3 with priority over aux and player inputs, level selectable
Indicator lights for power, signal, clip, priority and protection activation
Induction cooling, fanless. Silent and maintenance-free
CONTROLS
Microphone volume
Mic/line/phantom selector, ring tones and priority
Master volume
Selector for aux inputs or player
Zones with power on and 7 volume positions
Tone: bass and treble (+/- 10 dB 100 Hz and 10k Hz)
Ring tone level
Priority activation signal level (VOX)
PLAYER
USB/FM player for background music playback
Autoplay, playback starts automatically when power is switched on
Memory of last selected mode
Play mode memory (random, repeat)
IMPEDANCE
4 Ω and 100 V line (83 Ω), euroblock
TEMPERATURE
Operation: -10º ~ 40ºC
Storage: -20º ~ 60ºC
MAXIMUM
90%
HUMIDITY
POWER SUPPLY
230/115 V AC 50-60 Hz,
Power consumption: 175 W
AC fuse 230 V 2 A/115 V 4 A
DIMENSIONS
430 x 89 x 320 mm depth
ACCESSORIES
FM Antenna
Power cable
Rack mounts
- 7 -
EN
loading