STEINEL IS 2180 ECO Manual Del Usuario página 17

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
b) Connect service lead
The service supply lead
to the light is also a 2 to
3-core cable. Connect the
light's current-carrying
conductor to the terminal
marked L'. The service lead
neutral conductor must be
connected to the terminal
marked N together with the
Installation using corner wall mount
Functions
Once you have connected
the unit to the mains power
supply, closed the housing
and fitted the lens, you are
10 sec.-15. min.
2 - 2000 lux
mains lead neutral conduc-
tor. Connect the protective-
earth conductor to the
earth contact (
).
7. Screw on housing
and close again.
8. Fit lens (set reach to
either 5 m or 12 m max),
see 'Reach setting' section.
ready to put the system
into operation. Two setting
controls are concealed
behind the front cover 2.
Switch­off delay
(time setting)
The chosen light ON time
can be varied continuously
from approx. 10 sec. to a
maximum of 15 min. Turn-
ing the adjustment screw
fully anti-clockwise selects
the shortest time of approx.
5 sec., turning the adjust-
Twilight setting
(response threshold)
The chosen detector
response threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
Turning the adjustment
screw fully anti-clockwise
selects daylight operation
at approx. 2000 lux.
– 15 –
9. Select time 5 and light
threshold setting 4 (see
'Functions' section).
10. Locate front cover 2
and fit security screw 1 to
protect cover from unau-
thorised removal.
Important: Reversing the
connections may result in
damage to the unit.
With the corner wall brack-
ets, the IS 2180 ECO can
be conveniently mounted
on inside and outside
corners. Use the corner
wall bracket as a drilling
template when drilling the
holes. In this way you place
the drill hole at the right
angle and the corner wall
bracket can be mounted
without any problems.
The corner wall brackets
(EAN 40071085131 black /
40071085148 white) are
available as accessories.
Important: Only carry out
time and light threshold
settings with the lens fitted.
ment screw fully clockwise
the longest time of approx.
15 min. The shortest time
setting is recommended
for setting the detection
zone and performing the
walk test.
Turning the adjustment
screw fully clockwise
selects twilight operation
at approx. 2 lux. The
adjustment screw must be
turned fully anti-clockwise
for setting the detection
zone and performing the
walk test in daylight.
loading