3.3. Working with the unit
Before working with the unit, connect the necessary power cords to the unit.
Familiarize yourself with the parameters/functions of the unit. After starting the
system, set the desired parameters as described below.
CAUTION! When the unit is first connected to the mains and the cooling
temperature is programmed (or after a long break from use), there may be a
temperature difference between the setpoint (displayed on the control panel) and
the temperature inside the refrigeration compartment. This temperature will
stabilize with continuous operation of the unit. Do not open the unit door during
the temperature stabilization process. If the unit shuts down during the cooling
process, wait about 5 minutes before restarting the system (otherwise the unit will
not turn on).
3.3.1.
STARTING THE UNIT / TEMPERATURE SETTINGS
CAUTION! Any configuration of the cooling chamber cooling temperature,
generates increased operation of the refrigerant circuit, which may lead to the unit
housing reaching high temperatures. Once the system reaches the set threshold
value, the unit panels will gradually cool down until the temperature value around
the unit is reached.
MODEL RCWI-4G
a) The unit is started using the control panel, located in the central part of the
cooling chamber.
b) To start the system, simultaneously select and hold the buttons (b, c) for about
5 seconds for LED lighting and temperature control.
c)
The refrigeration compartment of the unit includes two cooling zones: upper
and lower. Temperature configuration should be carried out separately, for
each of them.
d) CAUTION! The upper and lower cooling zones have the same temperature
control range. When defining the cooling value of the upper zone, the system
will automatically assign the given value to the lower zone. The lower zone of
the refrigeration compartment, can have the same chilling temperature value
or higher, than the upper zone of the refrigeration compartment. The
temperature difference between the cooling zones is recommended to be no
more than 4 °C.
e) To set the chilling temperature value, select the temperature control button
(c) from the control panel.
•
A single selection of the adjustment button (c) will display the current chilling
temperature value on the LCD screen.