3.2. Preparation for operation
POSITIONING OF THE UNIT
The ambient temperature for each model must not exceed the following range: 10-
32°C - model RCWI-4G; 16-38°C - model RCWI-6G; 10-38°C - model RCWI-7G. Place
the unit in a way that ensures good air circulation. Maintain a minimum distance of
30 cm between the rear wall of the unit. Keep the unit away from any hot surfaces.
Always operate the unit on a level, stable, clean, fireproof and dry surface and out
of the reach of children and persons of impaired mental, sensory and intellectual
functions. Place the unit in such a way that the mains plug can be reached at any
time. Ensure that the power supply to the unit corresponds to that specified on the
identification plate!
BEFORE INITIAL USE
Before the first use, disassemble all components and wash them as well as wash the
interior
CAUTION! Before the unit is connected to the mains, it may generate a characteristic
odor, which will gradually escape as the unit reaches the programmed temperature.
ASSEMBLY OF THE UNIT
The unit has a right-hand door configuration at the factory, but it is possible to install
the door as a left-hand door according to the user's preference. The unit is designed
for free-standing or built-in operation.
a) CAUTION! Before proceeding to the removal / installation of the door, properly
secure the unit so that no damage occurs. Remove all moving parts from inside
the unit. Before tilting the unit, protect the refrigerant system circuit by laying
a soft material at the surface contact point!
b) To change the installation side of the door, laying the unit on the rear panel is
recommended.
c)
Holding the unit door, remove the lower hinge by unscrewing its fastenings
(Figure A).
d) Carefully slide the door out of the upper hinge pin (Fig. B). Place the removed
door in a safe place, with the outer panel up.
e) CAUTION! Pay attention to the set of removed fixings. Check that the fixings are
not left where the door meets the housing, seal, etc.
f)
Remove the upper hinge of the unit door by unscrewing its fastenings (Figure
C).
g) In the upper left corner of the unit in the place of fixing the hinge, lever up and
remove the covers of the mounting holes (Fig. D).
h) Cover the mounting holes left by the hinge mountings of the right side with the
previously removed covers (Fig. E).
i)
Install the left side hinge, screwing its mountings into the designated mounting
holes (Fig. F).
and
exterior
of
the
unit.