Genius JA668 Instrucciones Para El Uso página 7

ENGLISH
6.4
FAIL SAFE
Programming the microswitch SW9 enables to activate
and disactivate the Fail Safe function which, at each
activation, checks correct operation of the safety
devices installed, if supplied by the proper contact on
the terminal board.
6.5
PRE-FLASHING
Use microswitch SW10 to select a 5-second pre-flashing
before the door movement starts.
6.6
OPERATING LOGIC
CLOSING LIMIT-SWITCH
Use microswitches SW11 and SW12 to select four
different operating modes of the closing limit-switch. This
setting has no effect on the opening limit-switch, which
stops immediately.
7.
INPUTS EFFECT ON DOOR STATUS
7.1
AUTOMATIC LOGIC
DOOR
OPEN
STATUS
CLOSED
opens and closes after
pause time (1)
OPEN ON
re-counts
PAUSE
pause time
CLOSING
reverses movement
OPENING
no effect
LOCKED
closes (1)
7.2
SEMI-AUTOMATIC LOGIC
DOOR
OPEN
STATUS
CLOSED
opens (1)
OPEN
closes (1)
CLOSING
reverses movement
OPENING
l o cks
LOCKED
closes (1)
(1) when pre-flashing is selected, movement begins after pre-flashing time has elapsed.
8.
AUTOMATED SYSTEM TEST
The control board effects an electronic control (motor must be connected) before every start. If you try to make the
control board operate without any motor load or insufficient load, no power is supplied at motor output.
Check the correct rotation direction:
1)
Cut power to the system.
2)
Move the door by hand to mid-open position.
3)
Lock the operator
4)
Power up.
5)
Send an opening pulse (OPEN) and check if the motor opens the door.
If the door closes, reverse the phases of the electric motor (brown and black wires) on the control board terminal
board.
PULSES
STOP
CLOSING SAFETY
DEVICES
no effect
no effect
(disables opening)
stops
no effect
pause time count
(disables closing)
l o cks
reverses movement
l o cks
no effect
no effect
no effect
(disables closing)
(disables closing)
PULSES
STOP
CLOSING SAFETY
DEVICES
no effect
no effect
(disables opening)
no effect
no effect
(disables closing)
reverses movement
l o cks
l o cks
no effect
no effect
no effect
(disables closing)
(disables closing)
SW9 Fail safe
on
active
off
disabled
Fig. 5
ON
OFF
SW11 SW12 Logic
on
on
Stops immediately
off
on
decelerates for 5 sec.
on
off
continues at full speed for 5 sec.
off
off
decelerates for 4 sec. + 1 end sec. at full speed
OPENING SAFETY
DEVICES
no effect
(disables opening)
no effect
no effect
reverses movement
no effect
OPENING SAFETY
DEVICES
no effect
(disables opening)
no effect
no effect
reverses movement
no effect
8
SW10 Pre-flashing
on
active
off
disabled
1 2 3 4 5 6 7 8 9 101112
loading