PAINT SPRAYER PFS 450 A1
Introduction
Congratulations on the purchase of your new
appliance. You have chosen a high-quality product.
The operating instructions are part of this product.
They contain important information about safety,
usage and disposal. Before using the product,
please familiarise yourself with all operating and
safety instructions. Use the product only as
described and for the range of applications speci-
fied. Please also pass these operating instructions
on to any future owner.
Intended use
This appliance is suitable for applying paint,
lacquers and glazes. The use of easily flammable,
combustible paints, lacquers or thinners is strictly
prohibited.You can use the appliance to process
spray material with a flow time of up to 70 seconds
(max.). Any other usage of or modification to the
appliance is deemed to be improper and carries a
significant risk of accidents. The manufacturer
accepts no responsibility for damage(s) resulting
from improper usage. This tool is intended for
domestic use only.
Features
Union nut
Nozzle head
Nozzle
Spray unit
Trigger
Lock
5a
Motor unit
Screws
Air filter cover
Air filter
Paint cup
Riser pipe
Spray volume adjusting wheel
2 
GB │ IE
Cleaning brush
Cleaning needle
Measuring cup
Replacement air filter
Package contents
1 paint sprayer
4 nozzles 1,5 mm, 1,8 mm, 2,2 mm, 2,6 mm*
1 viscosity measuring cup
1 cleaning needle
1 cleaning brush
1 set of operating instructions
1 filter
*1 x prefitted
Technical data
Rated output
Rated voltage
Output
Paint cup
Max. viscosity
Protection type
Noise and vibration data
Noise measurement value determined in accord-
ance with EN 60745. The A-rated noise level of
the power tool is typically as follows:
Sound pressure level
Uncertainty
Sound power level
Uncertainty
Wear hearing protection!
Total vibration value of the handle:
Uncertainty
Symbols on the appliance
Always wear safety goggles.
Always wear a mask.
450 W
230 V ∼, 50 Hz (AC)
950 ml/min (water)
1200 ml
70 DIN/s
II /
(double insulation)
L
= 78 dB (A)
pA
K
=
3
dB
pA
L
= 89 dB (A)
WA
K
=
3
dB
WA
a
< 2,5 m/s
h
K = 1.5 m/s
PFS 450 A1