4.2.4. TIME SETTING*
*Only in wireless thermostat
To set or modify the time do as follows:
1) Set the thermostat to OFF and press short on the icon
access icons (Fig. 3).
2) Press hold on the time digits
setting process (meanwhile time is not set, time indication will display slashes --:--).
3) User selection arrows
set hour and minutes
4) Set Year (y) , month (m) and day (d) of the week by means of the selection arrows
and confirm with a short press on
5) Finally, select wether you want your system to automatically actualize time or not by
selection yes-nO for the parameter auto.
4.2.5 WARNING OF THE SYSTEM.
• DOOR: Window active: If your system is managing the opening of the window and this alert is
active, a message will be displayed, shutting the air conditioning. Once the alert is
deactivated, the zone will return to its previous status.
• PRES: Presence detected: If your system is managing the presence detection and this alert is
active, a message will be displayed, activating the Sleep Mode with a shut-off time of 90
minutes. Once the alert is deactivated, the zone will return to its previous status.
• HUMI: Humidity active. In case of having humidity monitoring integrated in your system to
control cooling radiant floor and it activates the alert, a message will be displayed, shutting
off the water supply for the cooling floor. Once the alert is deactivated, the zone will return to
its previous status.
• ACS: Domestic hot water active. In case of integrating DHW management in your equipment
system and it activates the alert, a message will be displayed, shutting off the climatization
of the zone. Once the alert is deactivated, the zone will return to its previous status.
• ERR9: Air conditioning communication error. In the case of losing communications with the
indoor air conditioning unit, a message will be displayed, system will open every motorized
outlet and control from the air conditioning controller will be enabled. Once the incidence is
solved, the system will return to its previous status.
• AN: Antifreezing active. If your system is managing the Anti-freezing functionality and it is
activated (see point 4.4, user menu), a message will be displayed, avoiding that the zone
goes below 12ºC. Once the alert is deactivated, the zone will return to its previous status.
48
until they blink indicating the access to the time
and confirm with a short pres son
.
.
; it will show direct
to sequentially