Manufac-
Product
turer
Schülke &
Mikrozid
Mayr
Liquid
Based on the following material compat-
ibilities, you can assess which other
cleaning agents and disinfectants are
suitable.
The anodized aluminum components
and seals of the tattoo machine are re-
sistant to:
Weak acids (e.g. boric acid ≤ 10%,
O
acetic acid ≤ 10%, citric acid ≤ 10%)
Aliphatic hydrocarbons (e.g. pentane,
O
hexane)
Ethanol
O
Most inorganic salts and their aque-
O
ous solutions (e.g. sodium chloride,
calcium chloride, magnesium sul-
phate)
Cheyenne HAWK Pen Unio
The anodized aluminum components
Exposure
and seals of the tattoo machine are not
time
resistant to:
1 to 2 mins
Strong acids (e.g. hydrochloric acid
O
≥ 20%, sulphuric acid ≥ 50%, nitric
acid ≥ 15%)
Oxidizing acids (e.g. peracetic acid)
O
Lyes (e.g. caustic soda, ammonia and
O
all substances with a pH value > 7)
Aromatic/halogenized hydrocarbons
O
(e.g. phenol, chloroform)
Acetone and benzene
O
7.2
Disinfecting surfaces
Before and after each usage:
Disinfect all surfaces of the tattoo
E
machine and its accessories as de-
scribed in chapter 5.2 on page 33.
7.3
Cleaning surfaces
In the event of external contamination:
Disassemble the grip and drive.
E
Wipe the grip, the drive and the pro-
E
tective sleeve with a soft cloth dipped
in a cleaning agent or a disinfectant.
Clean inaccessible surfaces, e.g. the
E
thread of the drive unit, with a soft-
bristled nylon brush or a swab.
Note that due to the surface quality,
E
streaks of ink may occur on the tattoo
machine.
7.4
Cleaning the drive ram
If the module shaft is dirty, you can sep-
arate the grip mount from the machine
to better access and clean the drive ram.
Completely unscrew the grip (1) from
E
the drive.
1
EN
39