Zenner zelsius C5-ISF Instrucciones De Instalación Y Funcionamiento página 17

Ocultar thumbs Ver también para zelsius C5-ISF:
Idiomas disponibles
  • ES

Idiomas disponibles

Be sure to read the installation and operating manual before installing /
commissioning completely. This allows you to protect yourself and prevent
damage. Check the contents of the packing before installation to be complete.
This installation and operating manual has to be handed over to the end user.
Designated use
Counting of thermal energy in heating and/or cooling plants (depending on meter
model) with closed heat exchanger circulation system and water (for special
versions of C5-ISF also for water glycol mixtures, not calibrated) as heat carrier. In
addition, instantaneous values (thermal power, flow of heat carrier, temperatures)
can be displayed.
Scope of supply
zelsius® C5-ISF resp. C5-CMF
1 seal or 2 seals (according to the model)
Seal material
Wall holder with mounting accessories (only for versions with detachable
calculator)
Installation and operating manual, declaration of conformity
Technical data (refer also to type plate)
Nominal flow q
p
Maximum flow q
s
Minimum flow q
ISF
i
Minimum flow q
CMF
i
Connection interface C5-CMF
acc. to DIN EN ISO 4064-4
Medium temperature range
Minimum pressure
(to avoid cavitation)
Nominal pressure /
peak pressure
IP protection class
Installation position
Heat carrier
Temperature range heat
calculator
Temperature difference range
Ambient class according to
EN 1434
Storage temperature
Interfaces
Ambient conditions /
Climatic influencing
(valid for complete compact
meter)
m³/h
0.6
m³/h
1.2
l/h
12 / 24
l/h
24
IST (G 2"), TE1 (M62x2), PCC (M60x2), M60
Thread
(M60x1.5), A1 (M77x1.5)
°C
10 ≤ Ө q ≤ 90
bar
0.3
PS/PN
16/16
54
(65 for combined heating and cooling
energy metering)
horizontal, horizontal tipped through 90 °,
vertical (for stand- or downpipe installation)
Water
(optional for C5-ISF: water glycol mixtures,
not calibrated)
0...105
°C
(approx. -20...+105 for C5-ISF for water glycol
heat carriers, not calibrated)
K
3...80
C
°C
-20...+65
Standard
optical interface (ZVEI, IrDA)
3 pulse inputs/outputs, M-Bus,
optional
wireless M-Bus, LoRa®
Highest permissible ambient temperature 55 °C
-climatic
Lowest permissible ambient temperature 5 °C
- mechanical
M1
class
- electromag-
E1
netic class
1.5
2.5
3.0
5.0
30 / 60
50 / 100
30 / 60
50 / 100
17
loading

Este manual también es adecuado para:

Zelsius c5-cmf