Maintenance; Draining The Tank; Checking The Oil; Changing The Oil - Porter Cable PXCM201 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MaIntenance

to avoid personal injury, always shut off and unplug the
waRnIng
I
compressor and relieve all air pressure from the system
before performing any service on the air compressor.
Regular maintenance will ensure trouble–free operation. Your electric powered
air compressor represents high–quality engineering and construction; however,
even high–quality machinery requires periodic maintenance. The items listed
below should be inspected on a regular basis

DRaInIng tHe tanK

waRnIng
I
moisture must be drained at the end of every workday.
waRnIng
I
air pressure in the system and open the petcock on the bottom of
the tank to drain.

cHecKIng tHe oIl

Check the level of oil in the pump with the sight glass. The pump oil level must
be between a and b (See Fig. 7). Do not overfill or underfill.

cHangIng tHe oIl

note: Use synthetic blend, nondetergent air compressor oil.
Remove the oil plug (c) (Fig. 7) and drain the oil until it slows to a drip, then
close. Add oil to the pump by first removing the breather plug (e). Add oil until
the level viewed through the sight glass (D) is between FULL (a) and ADD (b)
(approx. 17 oz). Never overfill or underfill the pump.
note: The compressor is pre-filled with synthetic oil. Use synthetic blend,
nondetergent air compressor oil.
a = full
b = add
c = oil drain plug
D = oil level sight glass
e = oil fill plug
MaIntenance
condensation will accumulate in the tank. to
prevent corrosion of the tank from the inside, this
be sure to wear protective eyewear. Relieve the
15 - ENG
Fig. 7
Tabla de contenido
loading

Tabla de contenido