Technical data
Type
Permissible Ex-area in gases
Permissible Ex-area in dusts
IP degree of protection
Dimensions (H x W x D)
Permissible size of cable entries
1)
Drill holes are to be made in the respective nominal
size in mm with a tolerance of up to +0.5 mm
Conductor connection to terminal
Dimensional drawing
Rated insulation voltage
Ambient temperature range
Impact resistance
22
KX 0202 C
II 3G Ex ec IIC T6 Gc
II 3D Ex tc IIIC T85 Dc
IP 66
93 x 93 x 62 mm
M20
10 mm
Cu
0.5 Nm
0,5 Nm
108
62
690 V a.c. / d.c.
Maximum value: + 40 °C
Minimum value: - 20 °C
For high mechanical risk level
= 7 Joule
KX 0404 C
KX 0606 C
II 3G Ex ec IIC T6 Gc
II 3D Ex tc IIIC T85 Dc
104 x 104 x 70 mm
130 x 130 x 77 mm
M20, M25
M20, M25, M32
10 mm
Cu
Cu
0.7 Nm
0,7 Nm
118
70
690 V a.c. / d.c.
Maximum value: + 40 °C
Minimum value: - 20 °C
For high mechanical risk level = 7 Joule
KX 1010 C
IP 66
180 x 130 x 77 mm
M20, M25, M32
12 mm
11 mm
Cu
1.5 Nm
2.0 Nm
1,5 Nm
2,0 Nm
141
141
77
77
23