Optional External Ground
for 3-Wire Connection
IMPORTANT: Y ou must verify with a qualified electrician
that this grounding method is acceptable before connecting.
1.
Prepare to connect neutral wire
A
Remove center terminal block screw (A) and green external
ground conductor screw (B).
2.
Connect neutral wire
A
Connect neutral wire (white or center) (C) of power supply
cord or cable under center terminal block screw (A).
Tighten screw.
78
B
C
3.
Connect remaining wires
Place ends of remaining wires under outer terminal block
screws. Tighten screws and tighten strain relief.
4.
Connect external ground wire
Connect a separate copper ground wire (D) under the green
external ground conductor screw (B) to an adequate ground.
Finally, install terminal block cover and secure with the three
screws. Now, go to "Route Drain Hose."
D
B