blueMatic EAV
EN
3.3.7
Frame power supply (separate) + terminal assignment
3
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
STK/RNT
green + white = Input for external potential-free contact
(e.g. unlocking via intercom system/open button)
50
white
+ 12 V DC
brown
- 0 V DC
green
For external
signal assign-
yellow
ment, see
grey
connection
pink
diagrams
white
+ 12 V DC
brown
- 0 V DC
For external
green
signal assign-
yellow
ment, see
grey
connection
pink
diagrams
P
230 V AC
N
Physical earth
Cable bushing for protection
in the profile drill hole
fasten with screw
(4 mm)
Metal
(reinforcement, profile)
5051251