Ferroli ROMEO N RF Manual De Usuario página 93

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
5.5 Room temperature probe fault
If the room temperature probe of the REMOTE is faulty, the display activates fault E92 and the symbol
. Heat-
ing is turned off.
5.6 External temperature probe fault
In Sliding Temperature mode, if the external temperature probe (optional) is faulty, the display activates fault E93
and the symbol
. The adjustment temperature becomes fixed at the "Heating temperature adjustment" value.
To eliminate the fault, restore the external probe or disable the Sliding Temperature adjustment.
5.7 REMOTE RF communication error with the RF base
In case of faults in radio communication between the REMOTE and the BRIDGE, all the displays associated with
the boiler are reset (including any errors) and after about 4 minutes of no communication, fault E94 is displayed.
5.8 Restoring factory settings
Attention! With this procedure all the parameters of the REMOTE will be returned to the factory value. It will
therefore be necessary to repeat the procedure for the automatic weekly program and reset the user parameters.
Press the buttons
/
together for 10 seconds: only the message RE blinking is displayed. Releasing
the buttons at any time before the end of the 10 seconds interrupts the procedure. After restoring, the REMOTE
activates all the symbols on the display.
EN
93
code 3542A980 - Rev. 00 - 01/2022
loading