7. OPERATION:
Alternating Current (AC) connection
WARNING:
Be sure any electric devices are turned o before plugging them in.
NOTICE
• Be sure all electric devices including the cables and plug connections are in good
condition before connection to the generator.
• Be sure the total load is within generator rated output.
• Be sure the receptacle load current is within receptacle rated current.
TIP:
Make sure to ground (Earth) the generator. If using an earthed electric device , the
generator must always be earthed.
1. Start the engine.
2. Turn the ESC to "ON".
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electric devices
TIP:
The ESC must be turned to "OFF" to increase engine speed to rated rpm.
If the generator is connected to multiple loads or electricity consumers, please
remember to rst connect the one with the highest starting current and lastly connect
the one with the lowest starting current.
4. Turn the fuel tank cap air vent
knob to "OFF" ③ after the engine
has completely cooled down.