The spa control system has automatic functions that operate
upon start-up and normal operation.
Upon power up, the display shows the following information:
I
current version of software: 356 in models with circulation
pump; 556 in models without circulation pump
I
"888" (all LED indicators are on: control of operation of all dis-
play segments and indicator lights).
I
After the initial start-up sequence ends, the actual water tem-
perature is displayed. If water temperature is below 38° C (fac-
tory setting) and the spa is set in skimming/heating mode "F1-
F3", the heater will come on. The heater goes off when water
temperature has reached 38° C.
N.B.: it is normal for the heater to turn on after the spa is first
filled because tap water is often very cold.
Setting water temperature
The spa's thermostat provides optimum control of water tem-
perature. The temperature set point (set temperature) can be ad-
justed from 18 °C to 40 °C. To increase the set temperature,
press button (+). To lower it, press ( – ).
N.B.: The first press of either WARMER ( + ) or COOLER ( - )
button displays the set temperature.
Pump activation
1
1
2
2
Button 1 activates the two-speed pump, the first press at low speed,
the second press at high speed. Pressing for a third time turns the pump
off. Button 2 activates pump 2, which only operates at high speed.
Button for spotlight/LED lighting system
This button makes it possible to turn the spa light on.
The light stays on for an hour. This time can be extended by
pressing the key again.
LED lighting system (optional)
Offers 7 fixed colours and 3 random sequence modes.
I
Press the "spotlight" button once to turn the light on in "random
and fadeout" mode. Then press the key repeatedly to turn the light
off or to select one of the 7 fixed colours, a random sequence of fixed
colours or a random sequence of flashing colours, in this order:
random with fadeout - off - WHITE - off - SKY BLUE - off
- VIOLET - off - BLUE - off - LIGHT GREEN - off - DARK
GREEN - off - RED - random steady colours - random
flashing colours - off.
I
Press the "Spotlight" button with no more than 3 seconds
between presses. If you press the key after 3 seconds the se-
quence starts over from the "random with fadeout" mode.
NOTE: Any time the light is manually turned on, it will auto-
matically turn off after approximately 1 hour.
Selecting desired massage action
Each model incorporates a massage selector that allows you
to customize the massage and performance by diverting wa-
ter between various jet systems.
Simply turn massage selector to position A (Combo), B o C, to
divert water pressure to various jet groups.
N.B.: The valve is designed to operate in positions A (Combo),
B, and C for optimum performance.
For optimum filtration benefits, leave the valve in position A
when spa is covered. Select position B or C for maximum jet
performance during spa use.
Adjusting Individual Jet Flow
The water flow to the individual jets in your spa can be increased
or decreased by rotating the outside jet face.
Many jets are also equipped with a direction adjustment mod-
ule, so that you can aim the jet in the desired position.
N.B.: always keep at least 5 jets open so as to ensure efficient
water filtering.
Air controls
Some jets have a dedicated air adjustment. Turn the knob clock-
wise to reduce the amount of air or counter-clockwise to in-
crease it.
To minimize heat loss, all air controls should be closed when
the spa is not in use.
Filter cycles
I
The control system activates a programmable "standard" or "e-
conomy" skimming/heating cycle. These cycles utilize pump #1
and the filter cartridge to clean the water quickly and minimize
their "bath-tub ring" effect.
22