True RMS Thermal MultiMeter / English
4.9.Temperature Measurements
• Set the function switch to the TEMP(°C or °F) position.
• Insert the Temperature Probe into the input jacks, making sure to
observe the correct polarity.
• Read the temperature in the display.
• Press the MODE key to switch the Unit (°C or °F).
4.10.Fexible Coil Current Measurements
• Set the function switch to the Flexible coil position.
• Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug
into the positive V jack.
• Read the currnet in the display.
• Press the MODE key to switch the AC ,DC and AC+DC Current.
• Press the RANGE key to switch range.1000mA,10A,30A,40A,100A,300A,400A,1000A,3000A.
10
4.11.DC Current Measurements
• Insert the black test lead banana plug into the negative COM jack.
• For current measurements up to 6000μA DC, set the function switch
to the μA position and insert the red test lead banana plug into the
μA/mA jack.
• For current measurements up to 600mA DC, set the function switch
to the mA position and insert the red test lead banana plug into the
μA/mA jack.
• For currentmeasurements up to 10A DC, set the function switch to
the 10A position and insert the red test lead banana plug into the
10A jack.
• Press the MODE button to indicate " " on the display.
• Read the current in the display.
4.12.AC Current Measurements
CAUTION: Do not make 10A current measurements for longer than 30
seconds. Exceeding 30 seconds may cause damage to the meter and/or
the test leads.
• Insert the black test lead banana plug into the negative COM jack.
• For current measurements up to 6000μA AC, set the function switch
to the yellow μA position and insert the red test lead banana plug
into the μA/mA jack.
• For current measurements up to 600mA AC, set the function switch
to the yellow mA position and insert the red test lead banana plug
into the μA/mA jack.
• For current measurements up to 10A AC, set the function switch to
the yellow 10A position and insert the red test lead banana plug into
the 10A jack.
• Press the MODE button to indicate " " on the display.
• Read the current in the display
19/07/2018 Version No. 001
19/07/2018 Version No. 001
True RMS Thermal MultiMeter / English
11