Tips And Recommendations For Installation - SOMFY Oximo io Manual

Ocultar thumbs Ver también para Oximo io:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION

2.4.1. Questions about the Oximo io?
Observations
The motor does not
work.
The blind stops too
soon.
The radio range is not
sufficient.
2.4.2. Readjusting manually set end limits
Go to the end limit you wish to alter.
1)
Simultaneously  press  the  up and down buttons
2)
until there is a brief movement (5 s).
Position the blind at the upper end limit using the
3)
transmitter's up and down buttons.
Press the "my" button until the blind moves briefly 
4)
(2 s).
For automatically set end limits, these are
automatically readjusted every 56 cycles, or after
a power outage.
2.4.3. Reversing the direction of rotation, motor
programmed
Position the blind outside of the end limits.
1)
Simultaneously  press  the  up and down buttons
2)
until the blind moves briefly (5 s).
Within in 5 seconds, press the "my" until the blind
3)
moves briefly (2 s).
The direction of rotation has been reversed.
2.4.4. Adding/Deleting Somfy io-homecontrol
Refer to the corresponding instructions.
2.4.6. Clearing the motor memory completely
Switch  the  motor  power  supply  off  then  back  on, 
1)
respecting the time periods.
After switching the power supply back on, the
-
blind moves extensively (5 s).
Press the "PROG" button until there are two brief
1)
movements of the blind (7 s).
Copyright © 2006-2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved. Images are not contractually binding.
The motor wiring
The thermal contact (wait for the motor to cool down).
The remote control battery.
The compatibility of the remote controls.
The remote control has been correctly memorised by the motor.
That the drive crown is securely attached to the tube (see 2.1. Installation).
That the motor end limits are correctly set (see 2.3. Commissioning).
That there is no radio interference.
Whether a repeater needs to be installed.
Check
1)
3)
1)
2)
control points and io sensors
®
1)
2)
EN
2)
4)
3)
7
Tabla de contenido
loading

Tabla de contenido