Enable open continuity test by default

This setting is used with continuity tests (see
beeper to sound and the backlight to flash as a continuity indication when the
circuit-under-test is more than or equal to (open) the threshold resistance.
Use this Setup item to enable the open continuity tests. During continuity tests,
press
or open continuity test (
Parameter
oPn
Figure 4-16

Changing the temperature unit

This setting is used with temperature measurements (see
combinations of displayed temperature unit(s) are available:
– Celsius only: Temperature measured in °C.
– Celsius/Fahrenheit: During temperature measurements, press
– Fahrenheit only: Temperature measured in °F.
– Fahrenheit/Celsius: During temperature measurements, press
Keysight U1231A, U1232A, and U1233A User's Guide
to switch between resistance measurement, short continuity test ( ),
Range
oPn.d or oPn.E
P ress
P ress
Enable open continuity test by default
between °C and °F.
between °F and °C.
page
).
Multimeter Setup Options
61). Enable this option for the
Defaul t setting
oPn.d
page
71). Four
4
to switch
to switch