STARTING AND STOPPING THE UNIT
Proceed as indicated.
Starting
1 -Press the switch (C)
GB
to enable the power
supply to the controls.
2 -When the display (G)
indicates "GEN OFF",
press the button (D) to
start the unit.
Important
When the unit starts up for the first
time the water pump is empty. Keep on
carrying out the start-up operation for
4/5 seconds until the water pump starts
to take in sea water (priming).
Stopping
1 -Press the switch (C) to turn the unit off.
Important
If the generator doesn't start, try only three times to start up it to avoid the sea
water entry. If the generator doesn't start, close the sea water inlet and proceed
to search the fault. Soon the generator starts up, open immediately the sea water
inlet.
PROLONGED INACTIVITY OF THE UNIT
In the event of prolonged inactivity of the
unit, a series of operations must be carried
out to guarantee proper operation when it
is used again.
– Drain the water circuit completely.
– Disconnect the battery.
– Turn the safety switch to the "0" (OFF)
position.
All manuals and user guides at all-guides.com
To restore the unit to operation after
a period of prolonged inactivity it is
recommended that you:
– Change the engine oil (see "Changing
engine oil" ).
– Change the fuel filter (see "Changing the
fuel filter").
– Change the sacrificial anode (see
"Changing the sacrificial anode").
-
-